We help the world since 2012
Input characteristic
Input voltage range:: 100~1000VDC(210-1200VDC)
Input current: 100VDC
PHV05 100mA , typ
PHV10 230mA , typ
PHV15 250mA , typ
surge current 10A (TYP) 100V 20A (TYP) 1200V
Output characteristic
Output voltage steady accuracy: ±1%
Original source effect: ±0.5% (typ)
Load adjust rate: (10%~100%) ±2% (typ)
Min load: 0%
Output ripple and noise(peak value): 100mV(typ) (20MHz Bandwidth)
Short-circuit protection long time Continuous,/automatic resume
Output over exceed current protection ≥1.1 times
General characteristic
Woking temperature: -40℃~+55℃
Power reduction rate:3.75% / ℃
Storage temperature:-40℃~+105℃
Outshell temperature:+80℃ max
Cut off current time:80ms(typ)/ at Vin:100VDC
Start delay time:500ms(typ)/ at Vin:1200VDC
Dynamic response: 25% standard load move rate ±4%/500uS
Humidity: 95% max
Temperature drift: 0.02%/℃
Switching frequency: 65-100kHz(typ)
Efficiency: 75%(typ)
Insolation: 4000VDC/1Min(special 3000VAC)
Insolation resistance input to output : 500Vdc 100000G
Leakage current:0.03mA RMS typ. 1200VDC
Saftey class: CLASS Ⅰ
MTBF: >215,000h @25℃
Products type
Input voltage and the load relationship characteristic
Dynamic load response
Size
outside shell size
sectional dimension:1.0mm terminal accuracy:0.1mm other accuracy: ±0.5mm